fbpx
Holiday Hours Update : In observance of the upcoming holidays, our Contact Support Centers will be open on December 24 until 3:00pm. We will be closed on December 25 and January 1. Wishing you and yours a Merry Christmas and Happy New Year!
HomeImplantsLocator Implant Overdenture
Locator® Implant Overdenture

Locator® Implant Overdenture

A removable implant-supported denture retained by Locator attachments that snap onto Locator abutments. Fabricated with an acrylic denture base, premium denture teeth, and metal housings.​
Appointment icon
5 Appointments
Full arch solution icon
Removable Full Arch Implant
flag icon
Made in USA
7 Years Warranty
1 Year Warranty
Locator Overdenture icon list
Retentive Caps Options
Retentive Caps Options
Attachment Cap​
Retention​
Black Processing​
Processing
Blue (Extra Light Retention)​
1.5 lbs.​
Pink (Light Retention)​
3.0 lbs.​
Clear​
5.0 lbs.​
Red (Extended Range – Extra Light Retention)
1.0 lbs.​
Orange (Extended Range)​
2.0 lbs.​
Green (Extended Range)​
4.0 lbs.​
Retentive Caps Options
Retentive Caps Options Chart- mobile

Supplemental Information

Indication
  • Edentulous patients seeking improved retention and stability compared to conventional dentures
  • Patients with 2 or more implants who prefer a removable solution
  • Cases where hygiene access and ease of maintenance are priorities
  • Patients unable to restore with fixed full-arch prosthesis due to anatomical or financial limitations
Contraindications
  • Patients unwilling or unable to remove and clean the prosthesis daily
  • Severe parafunctional habits without protective appliance
  • Inadequate implant positioning or insufficient restorative space
  • Patients desiring a fully fixed, non-removable restoration
Restorative Space Requirement​
  • Minimum 8–10 mm vertical space from implant platform to occlusal plane​
  • Additional clearance may be required based on attachment height and denture base thickness​
Implant Angulation​
  • Locator attachments can typically accommodate up to 20° divergence per implant​
  • Extended range inserts available for greater angulation correction​
Service Options​
  • Full-Service (Lab Pickup): Laboratory processes and picks up Locator attachments into the overdenture. Prosthesis is delivered fully completed and ready for insertion
  • Denture-Only Service (Chairside Pickup): Laboratory fabricates the overdenture with pre-formed attachment housings/relief spaces. Clinician performs final pickup of Locator attachments chairside using resin
Parts Included (Flat Rate)​
  • Final overdenture (acrylic base with premium denture teeth)
  • Locator housings and processing caps (Full-Service only)
  • Standard retention inserts (various retention levels)
  • Laboratory processing of attachments when applicable

Maximum Units / Bridge Design​

 

Typical workflow requires 4–5 clinical appointments:
  1. Implant-level impression or digital scan
  2. Wax rim / bite registration
  3. Wax try-in4. Attachment pickup and overdenture delivery5. Follow-up and retention adjustment
What to Send​
  • Implant-level impression or digital scan with Locator scan bodies
  • Opposing arch model or scan
  • Bite registration or wax rim
  • Shade and mold selection
  • Tissue shade preference (if applicable)
  • Clinical photos (recommended)